<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">ntv</journal-id><journal-title-group><journal-title xml:lang="ru">Научно-технический вестник информационных технологий, механики и оптики</journal-title><trans-title-group xml:lang="en"><trans-title>Scientific and Technical Journal of Information Technologies, Mechanics and Optics</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2226-1494</issn><issn pub-type="epub">2500-0373</issn><publisher><publisher-name>Университет ИТМО</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.17586/2226-1494-2026-26-1-116-124</article-id><article-id custom-type="elpub" pub-id-type="custom">ntv-570</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>КОМПЬЮТЕРНЫЕ СИСТЕМЫ И ИНФОРМАЦИОННЫЕ ТЕХНОЛОГИИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>COMPUTER SCIENCE</subject></subj-group></article-categories><title-group><article-title>Применение EtherCAT в отечественных медицинских изделиях с компьютерной томографией</article-title><trans-title-group xml:lang="en"><trans-title>Implementing EtherCAT for computed tomography featured medical devices</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6431-9094</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Рассудов</surname><given-names>Л. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Rassudov</surname><given-names>L. N.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Рассудов Лев Николаевич — кандидат технических наук, доцент</p><p>Москва, 111250</p><p>sc 57188955455</p></bio><bio xml:lang="en"><p>Lev N. Rassudov — PhD, Associate Professor</p><p>Moscow, 111250</p><p>sc 57188955455</p></bio><email xlink:type="simple">rassyd@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-9597-0522</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Осипов</surname><given-names>Д. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Osipov</surname><given-names>D. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Осипов Дмитрий Александрович — инженер</p><p>Москва, 111250</p><p>sc 59536295600</p></bio><bio xml:lang="en"><p>Dmitriy A. Osipov — Engineer</p><p>Moscow, 111250</p><p>sc 59536295600</p></bio><email xlink:type="simple">osipovdma09@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7859-5580</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Тяпкин</surname><given-names>М. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Tiapkin</surname><given-names>M. G.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Тяпкин Михаил Геннадьевич — кандидат технических наук,старший научный сотрудник</p><p>Москва, 111250</p><p>sc 57189248477</p></bio><bio xml:lang="en"><p>Mikhail G. Tiapkin — PhD, Senior Researcher</p><p>Moscow, 111250</p><p>sc 57189248477</p></bio><email xlink:type="simple">tiapkinmg@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Национальный исследовательский университет «МЭИ»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>National Research University “MPEI”</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>25</day><month>02</month><year>2026</year></pub-date><volume>26</volume><issue>1</issue><fpage>116</fpage><lpage>124</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Рассудов Л.Н., Осипов Д.А., Тяпкин М.Г., 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">Рассудов Л.Н., Осипов Д.А., Тяпкин М.Г.</copyright-holder><copyright-holder xml:lang="en">Rassudov L.N., Osipov D.A., Tiapkin M.G.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://ntv.elpub.ru/jour/article/view/570">https://ntv.elpub.ru/jour/article/view/570</self-uri><abstract><p>Введение. Компьютерная томография является мощным инструментом для диагностики, например, в онкологии, травматологии, стоматологии. Кроме того, компьютерная томография может применяться для проверки и коррекции позиционирования медицинского оборудования относительно тела пациента при проведении терапевтических процедур, например, брахитерапии или дистанционной лучевой терапии с визуальным контролем. В состав медицинских изделий с компьютерной томографией входит электроприводной механизм перемещения гантри — подвижной части аппарата, поддерживающей и перемещающей медицинское оборудование: рентгеновскую трубку и детектор рентгеновского излучения, радиационную головку и др. Улучшение возможностей синхронизации событий между компонентами медицинского оборудования и с системой движения открывает новые возможности построения архитектуры системы управления медицинских изделий. Применение промышленной шины жесткого реального времени Ethernet for Control Automation Technology (EtherCAT) может повысить скорость и безопасность проведения медицинских процедур. Метод. Предложена программно-аппаратная платформа, включающая ведущее и ведомое устройства EtherCAT. Ведущее устройство построено на основе программного обеспечения с открытым исходным кодом, в первую очередь, Linux и IgH, установленного на персональном компьютере. Ведомые устройства реализованы на доступной элементной базе. Исследованы возможности синхронизации событий ведомых устройств, а также стабильность работы EtherCAT на частоте 1 кГц.Основные результаты. Экспериментальные результаты получены на специально разработанном стенде. Ведущее устройство EtherCAT установлено на типовом персональном компьютере, а EtherCAT стек двух ведомых устройств реализован на распространенных микроконтроллерах. Показана возможность синхронизации событий в ведомых устройствах на уровне 0,1 мкс. Стабильность работы EtherCAT на базе предложенной платформы подтверждается высокой стабильностью измеренного времени цикла 1000 мкс с фазовым дрожанием (джиттером) на уровне единиц микросекунд. В сравнении с наиболее распространенным решением для построения ведущих устройств на базе персональных компьютеров The Total Windows Control and Automation Technology (TwinCAT), предложенная программная платформа продемонстрировала идентичные возможности синхронизации, но в несколько раз лучшую стабильность времени цикла EtherCAT. Обсуждение. Возможность использования доступных программных продуктов и элементной базы для разработки ведущего и ведомых устройств с последующим развертыванием сети EtherCAT позволит улучшить характеристики отечественных медицинских изделий компьютерной томографии и обеспечит высокий уровень производственной безопасности.</p></abstract><trans-abstract xml:lang="en"><p>Computed tomography is used for diagnostic purposes in various fields: oncology, traumatology, dentistry, etc. Additionally, it is implemented to provide the information on the correct patient positioning relative to therapeutic equipment for example in brachytherapy or in image guided radiation therapy complexes. As a rule, such installations include an electric power drive system for gantry — moving part of the apparatus holding medical equipment: X-ray tube and detector, radiation head et al. Improving the event synchronization between the components of medical equipment and those to the motion control system opens up new abilities for control system architecture design. Implementing a single real time fieldbus such as EtherCAT for data exchange between the subsystems can enable high level of synchronization expediting the therapy procedure and improving safety. A platform for deploying EtherCAT in medical devices is proposed. It includes EtherCAT master and slave implementations. The PC-deployed EtherCAT master is based on open-source software: Linux, IgH EtherCAT master stack. The slave devices are implemented with market available components. The stability of the EtherCAT cycle time at 1 kHz and the slave devices events synchronization abilities are being investigated. The experimental results obtained from a designed setup with such an EtherCAT master controlling two slave devices developed showed the ability to synchronize events between the two slave devices within a sub 100 ns range. The stability of the proposed EtherCAT platform was proved with the measured 1000 us EtherCAT cycle time jitter of a few microseconds. It is possible to improve the performance of medical devices with computed tomography by implementing the EtherCAT industrial network. The proposed solution, based on open-source software and market-available components, provides a high level of production safety.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>компьютерная томография</kwd><kwd>электрический привод</kwd><kwd>мехатроника</kwd><kwd>промышленные сети</kwd><kwd>системы реального времени</kwd><kwd>EtherCAT</kwd><kwd>синхронизация</kwd><kwd>открытый исходный код</kwd><kwd>операционная система</kwd><kwd>Linux</kwd></kwd-group><kwd-group xml:lang="en"><kwd>computed tomography</kwd><kwd>electric drives</kwd><kwd>mechatronics</kwd><kwd>X-ray imaging</kwd><kwd>motion control</kwd><kwd>real time systems</kwd><kwd>networked control systems</kwd><kwd>synchronization</kwd><kwd>open-source software</kwd><kwd>EtherCAT</kwd><kwd>operating system</kwd><kwd>Linux</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Авторы благодарят «Государственный научный центр Российской Федерации Троицкий институт инновационных и термоядерных исследований» (ГНЦ РФ ТРИНИТИ), Научно-исследовательский институт технической физики и автоматизации (НИИТФА) и Научно-производственный центр «Лазеры и аппаратура ТМ» за содействие в проведении исследования.</funding-statement><funding-statement xml:lang="en">The authors thank “State Research Center of the Russian Federation Troitsk Institute for Innovation and Fusion Research” (JSC “SRC RF TRINITI”), “Research Institute of Technical Physics and Automation” (JSC “NIITFA”) and Research and Production Center “Lasers and Apparatus TM” for assistance in conducting the research.</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Luke A.M., Shetty K.P., Satish S.V., Kilaru K. Comparison of spiral computed tomography and cone-beam computed tomography // Journal of Indian Academy of Oral Medicine and Radiology. 2013. V. 25. N 3. P. 173–177.</mixed-citation><mixed-citation xml:lang="en">Luke A.M., Shetty K.P., Satish S.V., Kilaru K. Comparison of spiral computed tomography and cone-beam computed tomography. Journal of Indian Academy of Oral Medicine and Radiology, 2013, vol. 25, no. 3, pp. 173–177.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Venkatesh E., Elluru S.V. Cone beam computed tomography: basics and applications in dentistry // Journal of Istanbul University Faculty of Dentistry. 2017. V. 51. N 3. P. S102–S121. https://doi.org/10.17096/jiufd.00289</mixed-citation><mixed-citation xml:lang="en">Venkatesh E., Elluru S.V. Cone beam computed tomography: basics and applications in dentistry. Journal of Istanbul University Faculty of Dentistry, 2017, vol. 51, no. 3, pp. S102–S121. https://doi.org/10.17096/jiufd.00289</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Karius A., Karolczak M., Strnad V., Bert C. Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy // Journal of Applied Clinical Medical Physics. 2022. V. 23. N 2. P. e13501. https://doi.org/10.1002/acm2.13501</mixed-citation><mixed-citation xml:lang="en">Karius A., Karolczak M., Strnad V., Bert C. Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy. Journal of Applied Clinical Medical Physics, 2022, vol. 23, no. 2, pp. e13501. https://doi.org/10.1002/acm2.13501</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Осипов Д.А., Рассудов Л.Н. Платформа для построения систем управления прецизионными электроприводами по промышленной шине EtherCAT//Вестник Московского энергетического института. 2025.№ 4.С. 31–36. https://doi.org/10.24160/1993-6982-2025-4-31-36</mixed-citation><mixed-citation xml:lang="en">Osipov D.A., Rassudov L.N. A platform for constructing precision electric drive control systems based on the ethercat industrial fieldbus. Bulletin of Moscow Power Engineering Institute, 2025, no. 4, pp. 31–36. (in Russian). https://doi.org/10.24160/1993-6982-2025-4-31-36</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Reniers B., Verhaegen F. Technical Note: Cone beam CT imaging for 3D image guided brachytherapy for gynecological HDR brachytherapy // Medical Physics. 2011. V. 38. N 5. P. 2762–2767. https://doi.org/10.1118/1.3578929</mixed-citation><mixed-citation xml:lang="en">Reniers B., Verhaegen F. Technical Note: Cone beam CT imaging for 3D image guided brachytherapy for gynecological HDR brachytherapy. Medical Physics, 2011, vol. 38, no. 5, pp. 2762–2767. https://doi.org/10.1118/1.3578929</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Karius A., Strnad V., Lotter M., Kreppner S., Bert C. First clinical experience with a novel, mobile cone-beam CT system for treatment quality assurance in brachytherapy // Strahlentherapie und Onkologie. 2022. V. 198. N 6. P. 573–581. https://doi.org/10.1007/s00066-022-01912-7</mixed-citation><mixed-citation xml:lang="en">Karius A., Strnad V., Lotter M., Kreppner S., Bert C. First clinical experience with a novel, mobile cone-beam CT system for treatment quality assurance in brachytherapy. Strahlentherapie und Onkologie, 2022, vol. 198, no. 6, pp. 573–581. https://doi.org/10.1007/s00066-022-01912-7</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Cho B. Intensity-modulated radiation therapy: a review with a physics perspective // Radiation Oncology Journal. 2018. V. 36. N 1. P. 1–10. https://doi.org/10.3857/roj.2018.00122</mixed-citation><mixed-citation xml:lang="en">Cho B. Intensity-modulated radiation therapy: a review with a physics perspective. Radiation Oncology Journal, 2018, vol. 36, no. 1, pp. 1–10. https://doi.org/10.3857/roj.2018.00122</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Kalender W.A. Principles and Applications of Spiral CT // Nuclear Medicine and Biology. 1994. V. 21. N 5. P. 693–699. https://doi.org/10.1016/0969-8051(94)90039-6</mixed-citation><mixed-citation xml:lang="en">Kalender W.A. Principles and Applications of Spiral CT. Nuclear Medicine and Biology, 1994, vol. 21, no. 5, pp. 693–699. https://doi.org/10.1016/0969-8051(94)90039-6</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Kachelriess M. Principles, design, and operation of multi-slice CT // Clinical Pet CT in Radiology Integrated Imaging in Oncology. 2011. P. 1–19. https://doi.org/10.1007/978-0-387-48902-5_1</mixed-citation><mixed-citation xml:lang="en">Kachelriess M. Principles, design, and operation of multi-slice CT. Clinical Pet CT in Radiology Integrated Imaging in Oncology, 2011, pp. 1–19. https://doi.org/10.1007/978-0-387-48902-5_1</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Леденев В. Аппараты КТ (компьютерные томографы) — виды и особенности. [Электрон. ресурс] https://mrt-vmsk.ru/blog-opisanieapparaty-kt-kompyuternye-tomografy/ (дата обращения 01.08.2025)</mixed-citation><mixed-citation xml:lang="en">Ledenev V. Computed Tomographs (CT) Scanners — Types and Features. Available at: https://mrt-vmsk.ru/blog-opisanie-apparatykt-kompyuternye-tomografy/ (accessed: 01.08.2025). (in Russian)</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Sorcini B., Tilikidis A. Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform) // Cancer/ Radiothérapie. 2006. V. 10. N 5. P. 252–257. https://doi.org/10.1016/j.canrad.2006.05.012</mixed-citation><mixed-citation xml:lang="en">Sorcini B., Tilikidis A. Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform). Cancer/ Radiothérapie, 2006, vol. 10, no. 5, pp. 252–257. https://doi.org/10.1016/j.canrad.2006.05.012</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Franzone P., Fiorentino A., Barra S., Cante D., Masini L., Cazzulo E., et al. Image‑guided radiation therapy (IGRT): practical recommendations of Italian Association of Radiation Oncology (AIRO) // La Radiologia Medica. 2016. V. 121. N 12. P. 958–965. https://doi.org/10.1007/s11547-016-0674-x</mixed-citation><mixed-citation xml:lang="en">Franzone P., Fiorentino A., Barra S., Cante D., Masini L., Cazzulo E., et al. Image‑guided radiation therapy (IGRT): practical recommendations of Italian Association of Radiation Oncology (AIRO). La Radiologia Medica, 2016, vol. 121, no. 12, pp. 958–965. https://doi.org/10.1007/s11547-016-0674-x</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">BECKHOFF Automation and IntraOp medical of U.S.A. Innovative radiation therapy uses flexible PC-based control platform // PC Control Magazine. 2013. N 2.</mixed-citation><mixed-citation xml:lang="en">BECKHOFF Automation and IntraOp medical of U.S.A. Innovative radiation therapy uses flexible PC-based control platform. PC Control Magazine, 2013, no. 2.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Delgado R., Hong C.H., Shin W.C., Choi B. Implementation and performance analysis of an etherCAT master on the latest real-time embedded linux // International Journal of Applied Engineering Research. 2015. V. 10. N 24. P. 44603–44609.</mixed-citation><mixed-citation xml:lang="en">Delgado R., Hong C.H., Shin W.C., Choi B. Implementation and performance analysis of an etherCAT master on the latest real-time embedded linux. International Journal of Applied Engineering Research, 2015, vol. 10, no. 24, pp. 44603–44609.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Свидетельство о государственной регистрации программы для ЭВМ № 2025619816 Российская Федерация. Программа «Программный комплекс для построения систем управления электроприводами по промышленной шине EtherCAT»: № 2025617474 заявлено 04.04.2025. опубликовано 18.04.2025. Бюл. № 4 / Осипов Д.А., Рассудов Л.Н. заявитель Федеральное государственное бюджетное образовательное учреждение высшего образования «Национальный исследовательский университет «МЭИ».</mixed-citation><mixed-citation xml:lang="en">Osipov D.A., Rassudov L.N. Software package for building electric drive control systems via the EtherCAT industrial bus. Certificate of the State computer program registration RU 2025619816. 2025. (in Russian)</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Cereia M., Bertolotti I.C., Scanzio S. Performance of a real-time EtherCAT master under Linux // IEEE Transactions on Industrial Informatics. 2011.</mixed-citation><mixed-citation xml:lang="en">Cereia M., Bertolotti I.C., Scanzio S. Performance of a real-time EtherCAT master under Linux. IEEE Transactions on Industrial Informatics, 2011, vol. 7, no. 4, pp. 679–687. https://doi.org/10.1109/tii.2011.2166777</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
