Preview

Scientific and Technical Journal of Information Technologies, Mechanics and Optics

Advanced search

Visual display system of changes in physiological states for patients with chronic disorders and data transmission via optical wireless communication

https://doi.org/10.17586/2226-1494-2022-22-5-951-961

Abstract

A visual display system of changes in the physiological state of patients and their data transmission via optical wireless communication is presented. Existing methods such as bedside monitors do not provide the possibility of visual display of information near the object in conditions of high workload of personnel and allow transmitting data via an electric cable or remotely in the radio frequency range. Such disadvantages reduce the responsiveness of personnel and lead to numerous errors in the transmitted data. A remote operational monitoring system is more effective, providing data collection from sensors, display with minimal delay time and data transmission over an interference-free communication channel in the optical range. A simple and visual way of displaying information allows to quickly and accurately recognize critical situations. The proposed system has two channels. The first channel provides a visual representation of changes in the physiological state on the visual display device in the form of a bracelet. The second channel allows transmitting data about the deviation in the patient’s condition via optical wireless communication in the infrared range of the spectrum for detailed display on a computer. The visual representation of changes in the physiological state is based on programmable change in the color of the LED indicators and on change in their operation modes. The block diagram and design of the visual display and data transmission system are presented. As part of the evaluation of the system operability, the heating of the visual display device in the COMSOL Multiphysics was evaluated. It is shown, that the average heating temperature of the indicator part in contact with human skin does not exceed 24 °C and is safe for the patient. The optical scheme of the receiving unit and the transmitting module is presented. The optical model of the module is presented in the Zemax program. It is shown, that the required average optical power of the working spectral region is 235 μW for the four infrared LEDs and four photodiodes located at a distance of 1 meter. A description of the working layout of a visual display and data transmission device is presented, including a digital pulse sensor and blood oxygen level, a color control and data processing unit, a visual display device, and a data transmission unit. The LEDs operation modes and its compliance with the deviation of the controlled parameters were checked by a special microcontroller program of practical significance. The implementation of the developed system is relevant when monitoring the condition of the object of observation in cases where the use of the radio frequency range is limited and the stability of the data transmission channel to electromagnetic interference plays an important role.

About the Authors

S. A. Vostrikova
ITMO University
Russian Federation

Svetlana A. Vostrikova — Junior Researcher

Saint Petersburg, 197101



K. O. Pogorelova
ITMO University
Russian Federation

Kira O. Pogorelova — Engineer

Saint Petersburg, 197101



D. S. Shiryaev
ITMO University
Russian Federation

Daniil S. Shiryaev — Junior Researcher

Saint Petersburg, 197101



E. V. Tkacheva
ITMO University
Russian Federation

Ekaterina V. Tkacheva — Mentor

Saint Petersburg, 197101



N. A. Belyakov
ITMO University
Russian Federation

Nikita A. Belyakov — Junior Researcher

Saint Petersburg, 197101



Ya. N. Kovach
ITMO University
Russian Federation

Yakov N. Kovach — Engineer

Saint Petersburg, 197101



Yu. S. Andreev
ITMO University
Russian Federation

Yurii S. Andreev — Engineer

Saint Petersburg, 197101



I. G. Smirnova
ITMO University
Russian Federation

Irina G. Smirnova — PhD, Associate Professor, Associate Professor

Saint Petersburg, 197101

sc 57195684395



E. A. Kondratieva
Polenov Neurosurgical Institute (Branch of Almazov National Medical Research Centre); The S.M. Kirov Military Medical Academy; Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology
Russian Federation

Ekaterina A. Kondratieva — D. Sc (Medicine), Head of MCS Study Group; Senior Lecturer; Senior Researcher

Saint Petersburg, 191014

Saint Petersburg, 194044

Moscow, 107031

sc 57191545581



References

1. Bakulin I.S., Kremneva E.I., Kuznetsov A.V. et al. Chronic Disorders of Consciousness. Ed. by M.A. Piradov. Moscow, Gorjachaja linijaTelekom Publ., 2020, pp. 1–12. (in Russian)

2. Balogh D., Kittinger E., Benzer A., Hackl J. Noise in the ICU. Intensive Care Medicine, 1993, vol. 19, no. 6, pp. 343–346. https://doi.org/10.1007/BF01694709

3. Busch-Vishniac I., West J., Barnhill C., Hunter T., Orellana D., Chivukula R. Noise levels in Johns Hopkins Hospital. Journal of the Acoustical Society of America, 2005, vol. 118, no. 6, pp. 3629–45. https://doi.org/10.1121/1.2118327

4. Сhakole M., Jibhkate R., Choudhari A., Gawali S., Tule P. A healthcare monitoring system using wifi module. International Research Journal of Engineering and Technology (IRJET), 2017, vol. 4, no. 3, pp. 1413–1417.

5. Eremenko A.A., Rostunova N.V., Budagyan S.A., Kurnosov A.V. The personalized telemedical system of Obereg for remote patient’s monitoring. Messenger of Anesthesiology and Resuscitation, 2020, vol. 17, no. 5, pp. 87–94. (in Russian). https://doi.org/10.21292/2078-5658-2020-17-5-87-94

6. Malika, Charu Rana. An indoor wireless Zigbee based patient monitoring system for hospitals. International Journal of Engineering Sciences Research-IJESR, 2013, vol. 4, no. 2, pp. 792–795.

7. Navya K., Murthy M.B.R. A Zigbee based patient health monitoring system. International Journal of Engineering Research and Applications, 2013, vol. 3, no. 5, pp. 483–486.

8. Mariappan P., Raghavan D., Abdel Aleem S., Zobaa A. Effects of electromagnetic interference on the functional usage of medical equipment by 2G/3G/4G cellular phones: A review. Journal of Advanced Research, 2016, vol. 7, no. 5, pp. 727–38. https://doi.org/10.1016/j.jare.2016.04.004

9. Dhatchayeny D., Sewaiwar A., Tiwari S., Chung Y. Experimental biomedical EEG signal transmission using VLC. IEEE Sensors Journal, 2015, vol. 15, no. 10, pp. 5386–5387. https://doi.org/10.1109/JSEN.2015.2453200

10. Ali H., Ibtehaj Ahmad M.I., Malik A. Li-Fi based health monitoring system for infants. Proc. of the 2nd International Conference on Communication, Computing and Digital systems (C-CODE), 2019, pp. 69–72. https://doi.org/10.1109/C-CODE.2019.8681012

11. Guger C., Allison B., Kammerhofer A., Guttmann F., Von Oertzen T.J., Spataro R., La Bella V., Annen J., Laureys S., Heilinger A., Ortner R., Cho W. MindBEAGLE — A new system for the assessment and communication with patients with disorders of consciousness and complete locked-in syndrom. Proc. of the IEEE International Conference on Systems, Man, and Cybernetics (SMC), pp. 3008–3013. https://doi.org/10.1109/SMC.2017.8123086

12. Wilheim F.H., Roth W.T., Sackner M.A. The LifeShirt: An advanced system for ambulatory measurement of respiratory and cardiac function. Behavior Modification, 2003, vol. 27, no. 5, pp. 671–691. https://doi.org/10.1177/0145445503256321

13. Zhang Y., Poon C.C.Y., Chan C., Tsang M.W.W., Wu K. A health-shirt using e-textile materials for the continuous and cuffless monitoring of arterial blood pressure. Proc. of the 3rd IEEE-EMBS International Summer School and Symposium on Medical Devices and Biosensors (ISSS-MDBS), 2006, pp. 86–89. https://doi.org/10.1109/ISSMDBS.2006.360104

14. Chan C.H., Zhang Y.T. Continuous and long-term arterial blood pressure monitoring by using h-Shirt. Proc. of the 5th International Conference on Information Technology and Application in Biomedicine, 2008, pp. 267–269. https://doi.org/10.1109/ITAB.2008.4570615

15. Lee B.-Ch., Kim J.Y., Choi S.H., Yoon Y.H. Use of an externalcooling device for the treatment of heat stroke. Clinical and Experimental Emergency Medicine, 2014, vol. 1, pp. 62–64. https://doi.org/10.15441/ceem.14.004

16. Gogate U., Bakal J. Healthcare monitoring system based on wireless sensor network for cardiac patients. Biomedical and Pharmacology Journal, 2018, vol. 11, no. 3, pp. 1681–1688. https://doi.org/10.13005/bpj/1537

17. Vostrikova S.A., Pogorelova K.O., Shiryaev D.S., Polukhin I.S., Andreev Y.S., Smirnova I.G., Kondratieva E.A., Bougrov V.E. Visual display system of changes in physiological state for patients with chronic disorders. Scientific and Technical Journal of Information Technologies, Mechanics and Optics, 2022, vol. 22, no. 2, pp. 401– 409. (in Russian). https://doi.org/10.17586/2226-1494-2022-22-2-401-409

18. Lovik R.D., Abraham J.P., Sparrow E.M. Surrogate human tissue temperatures resulting from misalignment of antenna and implant during recharging of a neuromodulation device. Neuromodulation, 2011, vol. 14, no. 6, pp. 501–511. https://doi.org/10.1111/j.1525-1403.2011.00396.x


Review

For citations:


Vostrikova S.A., Pogorelova K.O., Shiryaev D.S., Tkacheva E.V., Belyakov N.A., Kovach Ya.N., Andreev Yu.S., Smirnova I.G., Kondratieva E.A. Visual display system of changes in physiological states for patients with chronic disorders and data transmission via optical wireless communication. Scientific and Technical Journal of Information Technologies, Mechanics and Optics. 2022;22(5):951-961. https://doi.org/10.17586/2226-1494-2022-22-5-951-961

Views: 9


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2226-1494 (Print)
ISSN 2500-0373 (Online)